May 15, 2019 at 15:29 comment added Ava Chow Some sequence numbers are allowed. The highest sequence number disables some things like RBF and relative lock times. That sequence number is allowed. The lower sequence numbers that allow those other features are also accepted. However anything lower than those will have the node reject the transaction as non-final.
May 15, 2019 at 12:34 comment added yrm23 Most people just say locktime and sequence number are used to prevent the mining of a transaction until a certain date, but not tell at which step the prevention happen and where the tx to go after the prevention. About the locktime, the prevention is very clear that happen at check tx for entering mempool; but for sequence that not clear for me.
May 15, 2019 at 12:11 comment added yrm23 Thanks Andrew. Are they the same situation for both locktime and sequence number? I ask that because the sequence number is original designed for hold tx in mempool, but some BIP modified it.
May 15, 2019 at 4:14 history answered Ava Chow CC BY-SA 4.0